Effects of light emissions from LCD monitors on public health
Yu, Wilson (author) Sidhu, Bobby (Advisor) Zitouni, Abderrachid (Advisor) British Columbia Institute of Technology School of Health Sciences (Degree granting institution) (editor) (translator)
Background: Evidence suggests that exposure to prolonged use of computer monitors may lead to eye discomforts such as eyestrain, blurred vision, headaches, as well as computer vision syndrome. With the increase of internet and computer use at school and work, it raises a serious concern on whether or not the users are affected negatively. Objectives: The following study focuses on estimating the risk of using computers at the British Columbia Technology of Institute (BCIT) laboratories to determine if there is sufficient room lighting (illuminance) and monitor brightness (luminance) to ensure the safety of students at the school. Methods: Illuminance and luminance were both measured by means of a calibrated Unfors Xi light detector connected to a base unit. Several areas of each environment and monitor were measured and average values were taken to ensure that the data was reliable. The data were compared to applicable standards to determine if room lighting and computer brightness at BCIT were appropriate for safe student use. Results: The average illuminance was measured to be 405.4 Lux when the recommended level is 500 Lux. The results are considered statistically significant (p-value = 2x10-6). On the other hand, the luminance measurements averaged a reading of 94.6 cd/cm2 when the recommended minimum luminance level is 80 cd/cm2 (p-value = 0.99964). Discussion: The collected data show that the illuminance inside the BCIT laboratories where testing was conducted is not sufficient while the luminance of computer screens was found acceptable. Conclusion: The measurement of the illuminance inside BCIT laboratories showed that room lighting was insufficient and alternations of the monitor's brightness were made to compensate for insufficient lighting. It is recommended to increase room lighting in the tested laboratories in order to have all areas of the laboratory sufficiently lit at all times. This is to ensure that all students at BCIT are provided with a safe and healthy environment for computer use.
© Wilson Yu, 2014. All rights reserved. No part of this work covered by the copyright heron may be reproduced or used in any form or by any means – graphics, electronic, or mechanical including photocopying, taping, or information storage and retrieval systems – without written permission of the author.
2014-08-08
9 pages
Project submitted in partial fulfillment of the requirement for the degree of Bachelor of Technology in Environmental Health, British Columbia Institute of Technology, 2014. Peer reviewed