BCIT Citations Collection | BCIT Institutional Repository

BCIT Citations Collection

Determination of ginsenoside content in Asian and North American ginseng raw materials and finished products by high-performance liquid chromatography
A single-laboratory validation study was conducted for the quantification of Rg1, Re, Rb1, Rc, Rb2, and Rd in Asian ginseng (Panax ginseng C.A. Meyer) and North American ginseng (Panax quinquefolius L.) raw materials and finished products by RP-HPLC. The extraction with aqueous methanol was optimized for whole root, powdered extract, and finished product (raw, tablet, and capsule matrixes) test articles. Root materials were treated with base to hydrolyze acidic malonyl ginsenosides to their neutral counterparts. Calibration curves for each ginsenoside were linear over the following ranges (microg/g): 5-394 for Rg1, 15-1188 for Re, 39-2981 for Rb1, 6-499 for Rc, 5-406 for Rb2, and 7-600 for Rd, all having a coefficient of determination (r2) of > or = 99.5%. The LOD for Rg1, Re, Rb1, Rc, Rb2, and Rd was determined to be 1.06, 1.25, 2.19, 1.24, 1.27, and 1.70 microg/mL, respectively. Quantitative determinations performed with eight test materials by two analysts over 3 days (n = 12) resulted in RSDr values that ranged from 1.11 to 7.61%., Peer-reviewed article, Published. Received May 10, 2011; Accepted by AP May 11, 2011.
Determination of β-N-methylamino-L-alanine, N-(2-aminoethyl)glycine, and 2,4-diaminobutyric acid in food products containing cyanobacteria by ultra-performance liquid chromatography and tandem mass spectrometry
A single-laboratory validation study was completed for the determination of β-N-methylamino-L-alanine (BMAA), N-(2-aminoethyl)glycine (AEG), and 2,4-diaminobutyric acid (DAB) in bulk natural health product supplements purchased from a health food store in Canada. BMAA and its isomers were extracted with acid hydrolysis to free analytes from protein association. Acid was removed with the residue evaporated to dryness and reconstituted with derivatization using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AccQ-Fluor). Chromatographic separation and detection were achieved using RP ultra-performance LC coupled to a tandem mass spectrometer operated in multiple reaction monitoring mode. Data from biological samples were evaluated for precision and accuracy across different days to ensure repeatability. Accuracy was assessed by spike recovery of biological samples using varying amino acid concentrations, with an average recovery across all samples of 108.6%. The analytical range was found to be 764-0.746 ng/mL prior to derivatization, thereby providing a linear range compatible with potentially widely varying analyte concentrations in commercial health food products. Both the U. S. Food and Drug Administration (FDA) and U. S. Pharmacopeia definitions were evaluated for determining method limits, with the FDA approach found to be most suitable having an LOD of 0.187 ng/mL and LLOQ of 0.746 ng/mL. BMAA in the collected specimens was detected at concentrations lower than 1 μg/g, while AEG and DAB were found at concentrations as high as 100 μg/g. Finding these analytes, even at low concentrations, has potential public health significance and suggests a need to screen such products prior to distribution. The method described provides a rapid, accurate, and precise method to facilitate that screening process., Peer-reviewed article, Published. Received April 15, 2015; Accepted by SG June 22, 2015.