BCIT Citations Collection | BCIT Institutional Repository

BCIT Citations Collection

Pages

Student emotions with an edu-game
Proceedings of 2013 Humaine Association Conference on Affective Computing and Intelligent Interaction, Geneva, Switzerland, 2-5 Sept. 2013. We present the results of a study that explored the emotions experienced by students during interaction with an educational game for math (Heroes of Math Island). Starting from emotion frameworks in affective computing and education, we considered a larger set of emotions than in related research. For emotion labeling, we employed a standard method that relies on trained judges to report emotions over 20-second intervals. However, we asked judges to report all observed emotions in each interval, as opposed to only choosing one, as is standard practice. This variation allows us to discuss the appropriateness of this interval for emotion labeling. We present a detailed analysis of inter-coder reliability, both aggregated and over individual students, that considers not only the matching by judges over emotion type, but also the number of emotions detected., Conference paper, Published., Peer reviewed
Students use new lab to test electrical and cybersecurity systems
2016 | 2017 Project Highlights Short piece about BCIT Smart Microgrid designs., Article, Published
Study on the mechanical and environmental properties of concrete containing cathode ray tube glass aggregate
Cathode ray tube (CRT) glass is considered a hazardous material due to its lead toxicity. In addition, current disposal practices are being phased out due to their adverse environmental impacts. In this project, CRT glass was used as a fine aggregate replacement in concrete. Life-cycle material characterization was conducted by evaluating the durability and strength of the CRT-Concrete. Leaching tests were also conducted to investigate whether the material meets drinking water limits for Pb. Test results show that the plastic state of the CRT-Concrete was affected by the angularity of the glass particles. Moreover, the compressive strength of CRT-Concrete met and exceeded that of the control specimen. However, CRT-Concrete was susceptible to expansive alkali-silica reactions when more than 10% CRT replacement was used. Environmental leaching results show that lead concentrations from CRT-Concrete are below the drinking water limits depending on the CRT volume replacement and if biopolymers are used., Peer reviewed, Peer reviewed article, Received 26 July 2012 ; Accepted 24 March 2013 ; Available online 28 April 2013., Durability, CRT, Heavy metals, Glass recycling, Waste management, Sustainable concrete
Suppression of positional errors in biological development
Cells in developing embryos behave according to their positions in the organism, and therefore seem to be receiving `positional information'. A widespread view of the mechanism for this is that each cell responds locally to the concentration level of some extracellular chemical which is distributed in a spatial gradient. For molecules conveying and receiving the positional signal, concentrations are likely to be low enough that, per individual cell, only a few thousand molecules may be involved. Fluctuations to be expected in these numbers (Poisson distribution) could readily lead to errors up to a few percent of embryo length in the reading of position. This is an intolerable level of error for some developmental pattern-forming events. Embryos must have means of suppressing such errors. We maintain that this requires communication between cells, and illustrate this by using the reaction part of two well-known Turing-type reaction–diffusion models as the local gradient reader. We show that switching on diffusion in these models leads to adequate suppression of positional errors., Peer-reviewed article, Published. Received 31 December 1997, Revised 20 July 1998, Accepted 21 July 1998, Available online 24 March 1999.
Suppression of Rho-kinase activity promotes axonal growth on inhibitory CNS substrates
Several molecules inhibit axonal growth cones and may account for the failure of central nervous system regeneration, including myelin proteins and various chondroitan sulfate proteoglycans expressed at the site of injury. Axonal growth inhibition by myelin and chondroitan sulfate proteoglycans may in part be controlled by Rho-GTPase, which mediates growth cone collapse. Here, we tested in vitro whether pharmacological inhibition of a major downstream effector of Rho, Rho-kinase, promotes axonal outgrowth from dorsal root ganglia grown on aggrecan. Aggrecan substrates stimulated Rho activity and were inhibitory to axonal growth. Y-27632 treatment promoted the growth of axons by 5- to 10-fold and induced “steamlined” growth cones with longer filopodia and smaller lamellipodia. Interestingly, more actin bundles reminiscent of stress fibers in the central domain of the growth cone were observed when grown on aggrecan compared to laminin. In addition, Y-27632 significantly promoted axonal growth on both myelin and adult rat spinal cord cryosections. Our data suggest that suppression of Rho-kinase activity may enhance axonal regeneration in the central nervous system., Peer-reviewed article, Published. Received 2 July 2002; Revised 24 October 2002; Accepted 28 October 2002; Available online 23 March 2003.
A survey of stakeholder perspectives on exoskeleton technology
Background Exoskeleton technology has potential benefits for wheelchair users' health and mobility. However, there are practical barriers to their everyday use as a mobility device. To further understand potential exoskeleton use, and facilitate the development of new technologies, a study was undertaken to explore perspectives of wheelchair users and healthcare professionals on reasons for use of exoskeleton technology, and the importance of a variety of device characteristics. Methods An online survey with quantitative and qualitative components was conducted with wheelchair users and healthcare professionals working directly with individuals with mobility impairments. Respondents rated whether they would use or recommend an exoskeleton for four potential reasons. Seventeen design features were rated and compared in terms of their importance. An exploratory factor analysis was conducted to categorize the 17 design features into meaningful groupings. Content analysis was used to identify themes for the open ended questions regarding reasons for use of an exoskeleton. Results 481 survey responses were analyzed, 354 from wheelchair users and 127 from healthcare professionals. The most highly rated reason for potential use or recommendation of an exoskeleton was health benefits. Of the 17 design features, 4 had a median rating of very important: minimization of falls risk, comfort, repair and maintenance cost, and purchase cost. Factor analysis identified two main categories of design features: Functional Activities and Technology Characteristics. Qualitative findings indicated that health and physical benefits, use for activity and access reasons, and psychosocial benefits were important considerations in whether to use or recommend an exoskeleton. Conclusions This study emphasizes the importance of developing future exoskeletons that are comfortable, affordable, minimize fall risk, and enable functional activities. Findings from this study can be utilized to inform the priorities for future development of this technology., Peer-reviewed article, Published. Submission date 13 September 2014 ; Acceptance date 12 December 2014 ; Publication date 19 December 2014.
Synthesis of galactofuranosyl-containing oligosaccharides corresponding to the glycosylinositolphospholipid of Trypanosomacruzi
The oligosaccharide β-d-Galf-(1→3)-α-d-Manp-(1→2)-[β-d-Galf-(1→3)]-α-d-Manp-(1→2)-α-d-Manp corresponds to the terminal end of the glycosylinositolphospholipid oligosaccharide of the protozoan Trypanosomacruzi, the causative agent of Chagas’ disease. Syntheses of methyl or ethylthio glycosides of the terminal disaccharide, trisaccharide, tetrasaccharide, and pentasaccharide corresponding to this structure are described. These syntheses employ the selective activation of a phenyl 1-selenogalactofuranoside or a phenyl 1-selenomannopyranoside donor over ethyl 1-thioglycoside acceptors with NIS–TfOH., Peer-reviewed article, Published. Received 8 December 1999; Accepted 14 December 1999; Available online 19 April 2000.
Taxonomizing features and methods for identifying at-risk students in computing courses
Proceedings from the 23rd Annual ACM Conference on Innovation and Technology in Computer Science Education. Since computing education began, we have sought to learn why students struggle in computer science and how to identify these at-risk students as early as possible. Due to the increasing availability of instrumented coding tools in introductory CS courses, the amount of direct observational data of student working patterns has increased significantly in the past decade, leading to a flurry of attempts to identify at-risk students using data mining techniques on code artifacts. The goal of this work is to produce a systematic literature review to describe the breadth of work being done on the identification of at-risk students in computing courses. In addition to the review itself, which will summarize key areas of work being completed in the field, we will present a taxonomy (based on data sources, methods, and contexts) to classify work in the area., Peer reviewed, Conference paper, Published.
Temperature and air flow patterns in attic roofs
Understanding temperature and airflow patterns in an attic roof helps to identify the sections of the roof where moisture damage and roofing material durability problems can be expected. In this paper, the temperature distribution and the airflow patterns inside an attic space in a climate that can be characterized with cold winter and hot summer periods are discussed. In the study, transient boundary conditions were applied, and the dynamic responses of a typical attic roof, including the flow patterns, attic air and roof sheathing temperatures, ventilation rates, and heating and cooling loads, are presented. These findings can be used to understand the airflow pattern and how it can be affected by an incoming wind speed and solar gain., Peer reviewed article, Published. Received: September 14, 2016; Accepted: March 08, 2017; Published online: June 22, 2017.
Temperature and humidity distributions in mid-rise residential building suites
14th Canadian Conference on Building Science and Technology, Toronto, Canada, October 29th-30th, 2014. It is essential to design and operate buildings with good indoor air quality as people spend most of their time indoor. Their productivity, comfort and health depend on the quality of the indoor air. In addition to other air quality parameters, indoor humidity and temperature need to be controlled and maintained to acceptable ranges. These conditions may not be uniform within the house/building due to local heat and moisture sources and absence of an effective indoor air mixing mechanism as in the case of in buildings with baseboard heating systems. Localized high humidity creates favourable conditions for localized mold growth, poor indoor air quality and building envelope damage. In this paper, the indoor humidity and temperature distributions within four suites (designated as Suite ‘A’, ‘B’, ‘C’ and ‘D’) in a six-storey multi-residential building are studied. A total of 22 rooms are monitored with indoor temperature and relative humidity data loggers, and the outdoor climatic conditions are measured with a weather station for over a year. The hygrothermal performances of exterior walls in the master bedrooms of the respective suites are assessed. Analysis of the measured data suggests that the temperature variations between the rooms (bedrooms, living room, kitchen excluding bathroom) are relatively low during the summer period (mean temperature difference less than 1oC) compared to the winter period where the variations between the rooms can be as high as 2oC. The excess humidity differences between the rooms, excluding the kitchens, are in the range of 0.2 g/m 3 to 1.0 g/m 3 during both winter and summer periods, whereas the excess humidity fluctuations within the rooms are fairly the same and have standard deviation values between 0.8 g/m 3 and 1.0 g/m 3. Excess humidity is defined as the difference between the indoor and outdoor absolute humidities, quantities that are derived from the simultaneously measured temperature and relative humidity of the indoor and outdoor locations. Hygrothermal simulation results of exterior wall systems indicate that, in a mild coastal climate, the winter average indoor relative humidity shall be below 43% (for a seasonal average indoor temperature of 20oC) to avoid building envelope moisture damage., Peer reviewed article, Published.
Thermal comfort
Meeting and exceeding requirements for indoor air quality, thermal comfort, and acoustic and visual quality can lead to optimized environments that maximize well-being and performance. However, surveys on numerous buildings have revealed that satisfactory indoor environmental conditions are often not achieved. This suggests the whole industry needs more systematic methods to analyze and design indoor environments., Peer reviewed, Technical feature, Published 2018., Thermal comfort, Thermal environmental quality, ASHRAE Standard 55-2017
Thermostat setback effect in whole building performance
Proceedings of Building Physics Symposium: 29 October 2008, Leuven, Belgium. This paper describes the use of a whole building hygrothermal model (HAMFitPlus) to analyze the energy savings resulting from three programmable thermostat setting schemes in a real occupied residential house. It discusses the effect of these schemes on the indoor relative humidity and moisture performance. In the first thermostat-setting scheme, the indoor temperature is maintained constant at 21 at all time (no set-back). In the second thermostat-setting scheme, the indoor temperature is maintained at 21ºC from 7:00 to 21:00 h, and then setback to 17ºC for the remaining hours (21:00 to 7:00 h)., Conference paper, Published. A version of this document is published in: Building Physics Symposium, Lueven, Belgium, October 29-31, 2008, pp. 1-5.

Pages