BCIT Citations Collection
Collection of published works from BCIT researchers, faculty, and instructors.
Pages
-
- An experimental study of the physicochemical properties of a cement matrix containing dredged materials
- Recently, the amount of dredged soil material (DM) has been rapidly increasing in Korea due to four major river maintenance projects and new harbor construction. DM waste is mostly dumped into the ocean, while only a small part of it has been utilized for coastal reclaiming, or as filling and backfilling material. This study carried out physical and chemical tests to map out a specific plan for utilizing DM in a mortar mixture. The compressive strength tests and microstructure analysis using XRD and SEM of cement mortar contained DM were performed as a replacement for fine aggregate or as a filler material of mortar matrix. The study measured the impact of contaminants contained in DM and how silt and clay influenced the compressive strength of the mortar., Peer-reviewed article, Published. Received April 7th, 2011; revised May 16th, 2011; accepted June 1st, 2011.
-
- An explicit model of belief change for cryptographic protocol verification
- Proceedings of the 8th International Symposium on Logical Formalizations of Commonsense Reasoning. Stanford, CA, 2007. Cryptographic protocols are structured sequences of messages that are used for exchanging information in a hostile environment. Many protocols have epistemic goals: a successful run of the protocol is intended to cause a participant to hold certain beliefs. As such, epistemic logics have been employed for the verification of cryptographic protocols. Although this approach to verification is explicitly concerned with changing beliefs, formal belief change operators have not been incorporated in previous work. In this preliminary paper, we introduce a new approach to protocol verification by combining a monotonic logic with a non-monotonic belief change operator. In this context, a protocol participant is able to retract beliefs in response to new information and a protocol participant is able to postulate the most plausible event explaining new information. Hence, protocol participants may draw conclusions from received messages in the same manner conclusions are drawn in formalizations of commonsense reasoning. We illustrate that this kind of reasoning is particularly important when protocol participants have incorrect beliefs., Conference paper, Published.
-
- An urban metabolism and ecological footprint assessment of Metro Vancouver
- As the world urbanizes, the role of cities in determining sustainability outcomes grows in importance. Cities are the dominant form of human habitat, and most of the world's resources are either directly or indirectly consumed in cities. Sustainable city analysis and management requires understanding the demands a city places on a wider geographical area and its ecological resource base. We present a detailed, integrated urban metabolism of residential consumption and ecological footprint analysis of the Vancouver metropolitan region for the year 2006. Our overall goal is to demonstrate the application of a bottom-up ecological footprint analysis using an urban metabolism framework at a metropolitan, regional scale. Our specific objectives are: a) to quantify energy and material consumption using locally generated data and b) to relate these data to global ecological carrying capacity. Although water is the largest material flow through Metro Vancouver (424,860,000 m3), it has the smallest ecological footprint (23,100 gha). Food (2,636,850 tonnes) contributes the largest component to the ecological footprint (4,514,400 gha) which includes crop and grazing land as well as carbon sinks required to sequester emissions from food production and distribution. Transportation fuels (3,339,000 m3) associated with motor vehicle operation and passenger air travel comprises the second largest material flow through the region and the largest source of carbon dioxide emissions (7,577,000 tonnes). Transportation also accounts for the second largest component of the EF (2,323,200 gha). Buildings account for the largest electricity flow (17,515,150 MWh) and constitute the third largest component of the EF (1,779,240 gha). Consumables (2,400,000 tonnes) comprise the fourth largest component of the EF (1,414,440 gha). Metro Vancouver's total Ecological Footprint in 2006 was 10,071,670 gha, an area approximately 36 times larger than the region itself. The EFA reveals that cropland and carbon sinks (forested land required to sequester carbon dioxide emissions) account for 90% of Metro Vancouver's overall demand for biocapacity. The per capita ecological footprint is 4.76 gha, nearly three times the per capita global supply of biocapacity. Note that this value excludes national government services that operate outside the region and could account for up to an additional 2 gha/ca., Peer-reviewed article, Published. Received 23 December 2011; Revised 25 February 2013; Accepted 5 March 2013; Available online 19 April 2013.
-
- Analysis of pattern precision shows that Drosophila segmentation develops substantial independence from gradients of maternal gene products
- We analyze the relation between maternal gradients and segmentation in Drosophila, by quantifying spatial precision in protein patterns. Segmentation is first seen in the striped expression patterns of the pair-rule genes, such as even-skipped (eve). We compare positional precision between Eve and the maternal gradients of Bicoid (Bcd) and Caudal (Cad) proteins, showing that Eve position could be initially specified by the maternal protein concentrations but that these do not have the precision to specify the mature striped pattern of Eve. By using spatial trends, we avoid possible complications in measuring single boundary precision (e.g., gap gene patterns) and can follow how precision changes in time. During nuclear cleavage cycles 13 and 14, we find that Eve becomes increasingly correlated with egg length, whereas Bcd does not. This finding suggests that the change in precision is part of a separation of segmentation from an absolute spatial measure, established by the maternal gradients, to one precise in relative (percent egg length) units., Peer-reviewed article, Published.
-
- Application of a Whole-Building Hygrothermal model in energy, durability, and indoor humidity retrofit design
- A building shall be classified as high performance building if it is energy efficient and durable and at the same time provides comfortable and healthy indoor environment for occupants. To achieve this objective, the hygrothermal performance of alternative building designs should be evaluated based on the simultaneous analysis of these three functional requirements rather than separately. In this article, a Whole-Building Hygrothermal model is used for evaluation of various retrofit design parameters that potentially enhance the overall performance of an existing residential house. The retrofit options considered in this study include changes to the reference house’s ventilation rate and operation, windows, insulation level, and various combinations of these options. Energy efficiency, building envelope and moisture management potential, indoor humidity control, and window condensation potentials are considered to be the four performance indicators in searching for a retrofit option that delivers an optimal performance. The hygrothermal simulation results indicate that changing a design parameter to improve one of the design goals may result in less optimal results in the other one or both goals, or even in some cases result in severe negative consequences., Peer reviewed article, Published. Article first published online: February 27, 2014; Issue published: July 1, 2015 .
-
- Application of hygrothermal analyses to optimize exterior wall design
- Proceedings of 2nd International Conference on Research in Building Physics: 14 September 2003, Leuven, Belgium. The design of exterior walls in a building envelope for optimum moisture management is a challenging task. Many conventional methods or local practice guidelines are available for this purpose, based primarily on regional traditions and with limited performance assessment records. In recent years, new wall systems and unconventional materials have been introduced in every part of North America for reasons such as aesthetic appeal, cost-effectiveness etc. However, neither the long-term moisture management performance of these new wall systems nor the uses of unconventional materials have been assessed rigorously. The primary reason for this lack of such assessment is the absence of a design-oriented technical routine toperform the task. Recent studies at the Institute for Research in Construction (IRC) / National Research Council (NRC) of Canada, show that such an assessment is possible with the use of an advanced hygrothermal modelling tool, such as hygIRC, developed in-house at IRC. This paper presents results from hygrothermal modelling and discussion on walls with the four different cladding systems: stucco, exterior insulated finish systems (EIFS), masonry and siding. These walls were virtually exposed to several North American climates. Their hygrothermal responses were assessed with a novel indicator, called the RHT index, which is derived from relative humidity and temperature. The results and discussion presented in this paper clearly show the need and usefulness of an integrated design methodology for the moisture management of exterior wall systems that can help to optimise various design considerations., Conference paper, Published. A version of this document is published in: Research in Building Physics, Leuven, Belgium, Sept. 14-18, 2003, pp. 417-426.
-
- Application of hygrothermal modeling tool to assess moisture response of exterior walls
- The moisture design of exterior walls in a building envelope is an important task that needs to be carried out systematically to generate a sustainable and healthy built environment. Many conventional methods or practice guidelines are available for this purpose, based primarily on local traditions and with limited performance assessment records. In recent years, with the rapid development of global free trade and economy, new wall systems and unconventional materials have been introduced in every part of the world for reasons such as aesthetic appeal, cost effectiveness and so on. However, neither the long-term moisture management performance of these new wall systems nor the uses of unconventional materials have been assessed in a systematic way. The primary reason for this lack of assessment is the absence of a design-oriented methodology to perform the task. This paper presents selected results from a recently completed research project that demonstrate that it is indeed possible to assess the moisture management performance of exterior walls in a systematic way, using a hygrothermal modeling tool together with key inputs from a limited number of laboratory and field investigations. In this project the hygrothermal responses of exterior walls and their components were assessed with a novel moisture response indicator, called the RHT index, which is derived from relative humidity and temperature data over a time period. The results and discussion presented in this paper clearly show the need and usefulness of the application of hygrothermal simulation tool for the optimum moisture design of exterior wall systems in various geographic locations, when sufficient information is available from laboratory and field experiments., Technical papers, Published. Received February 23, 2005; Accepted May 05, 2006; Published online December 01, 2006.
-
- Application of modeling tool to assess moisture and thermal performance of retrofitted wall assemblies
- Proceedings of CIB World Building Congress 2004: 02 May 2004, Toronto, Ontario. As the stock of buildings in Canada ages, it is expected that there will be an increase in building envelope rehabilitation work. Such activities represent an ideal opportunity to add insulation and reduce air leakage to improve energy efficiency and building envelope durability. However, there is very little information available on how to assess the moisture and thermal (i.e. energy) performance of retrofitted building envelope assemblies and select the optimum retrofit options that will maximize the energy efficiency without compromising the long-term moisture performance of the retrofitted building envelopes. This paper depicts selected results from a study that has used a two-dimensional hygrothermal simulation tool, hygIRC-2D, to assess thermal and moisture performance of retrofitted masonry walls used in high-rise construction. The performance analyses of three basic (i.e. base case) masonry wall systems (Brick Veneer - Steel Stud, Brick Veneer - Concrete Masonry, and Precast Concrete Panels - Steel Stud) with four retrofit options, located in the National Capital Region (Ottawa-Gatineau) of Canada, are presented in this paper. The results from the simulations indicate that hygrothermal simulation tools can be used to evaluate the thermal and moisture performance of various wall systems and associated retrofit options. Simulations results also indicate that with specific retrofit options the energy performance of the wall system can be improved significantly without compromising the moisture response of the wall by adding insulation and reducing air-leakage in the wall assembly. However, heat or energy loss through the wall system is directly proportional to the air-leakage characteristics of the wall system. In general, based on the results presented in this paper, it can be concluded that use of a hygrothermal simulation tool can help to identify potentially problematic retrofit strategies while more promising measures can be advanced for additional assessment through full-scale laboratory testing or field demonstration., Conference paper, Published. A version of this document is published in: CIB World Building Congress 2004, Toronto, Ontario, May 2-7, 2004, pp. 1-10.
-
- Arbitrary announcements in propositional belief revision
- Proceedings of the International Workshop on Defeasible and Ampliative Reasoning (DARe-15) in Buenos Aires, Argentina, July 27, 2015. Public announcements cause each agent in a group to modify their beliefs to incorporate some new piece of information, while simultaneously being aware that all other agents are doing the same. Given some fixed goal formula, it is natural to ask if there exists an announcement that will make the formula true in a multi-agent context. This problem is known to be undecidable in a general modal setting, where the presence of nested beliefs can lead to complex dynamics. In this paper, we consider not necessarily truthful public announcements in the setting of propositional belief revision. We are given a goal formula for each agent, and we are interested in finding a single announcement that will make each agent believe the corresponding goal following AGM-style belief revision. If the goals are inconsistent, then this can be seen as a form of ampliative reasoning. We prove that determining if there is an arbitrary public announcement in this setting is not only decidable, but that it is simpler than the corresponding problem in the most simplified modal logics. Moreover, we argue that propositional announcements and beliefs are sufficient for modelling many practical problems, including simple robot controllers., Conference paper, Published.
-
- Assessment of building retrofit options using hygrothermal analysis tool
- Proceedings of 7th Symposium on Building Physics in the Nordic Countries: 13 June 2005, Reykjavik, Iceland. As the stock of buildings in our society ages, it is expected that there will be an increase in building envelope rehabilitation work. Such activities represent an ideal opportunity to modify the existing wall system to improve building envelope durability and energy efficiency. This could be done by addition of insulation and sealing air leakage paths. However, there is very little information available on how to assess the moisture and energy (i.e. thermal) performance of retrofitted building envelope assemblies and select the optimum retrofit options that will maximize the long-term moisture performance and the energy efficiency of the retrofitted building envelopes together. This paper presents the findings from a study that has used a two-dimensional hygrothermal simulation tool, hygIRC-2D, to assess moisture and energy performance of retrofitted masonry walls used in high-rise construction for both residential and commercial types of buildings at various Canadian locations. The results from the simulations indicate that, if heat, air and moisture transport properties of the materials and the airflow characteristics of the systems can be defined properly a hygrothermal simulation tool can be used to evaluate the moisture and thermal (i.e. energy) performance of various wall systems and associated retrofit options., Published. A version of this document is published in: 7th Symposium on Building Physics in the Nordic Countries, Reykjavik, Iceland, June 13-15, 2005, pp. 1139-1146.
-
- Assessment of energy rating of polyurethane spray foam walls
- The application of polyurethane spray foam (SPF) insulation in buildings provides a durable and efficient thermal barrier. The industry is also promoting the SPF as an effective air barrier system in addition to its thermal insulation characteristics. In an effort to address these issues, a consortium of SPF manufacturers and contractors, jointly with the National Research Council of Canada’s Institute for Research in Construction conducted an extensive research project to assess the thermal and air leakage characteristics of SPF walls as well as conventional wall assemblies. The objective is to develop analytical and experimental procedures to determine a wall energy rating (WER) that captures both the thermal and airleakage performance of a wall assembly. The experimental part included two streams of testing: (1) To determine the wall air leakage rate at different conditions and (2) their thermal resistance, R-value, at different temperature differences. An analytical procedure was also developed to calculate WER by combining the heat loss due to thermal transmission and that due to air leakage with the aim of arriving at WER. Six conventional full-scale wood frame wall assemblies were built, two with glass fiber batts and of four with medium density SPF. Some walls were constructed without penetrations and others were built with penetrations. The testing regime included: (i) Initial testing of air leakage and thermal resistance; (ii) conditioning in the dynamic wall test facility according to an established routine; and (iii) retesting for air leakage and thermal resistance. This paper presents the results of six walls included in this project. The focus of this paper will be on presenting a brief summary of the project objective, testing protocol, and the theoretical approach to determine the WER number for the six walls., Peer reviewed article, Published. Received 23 July 2008; accepted 30 June 2009; published online 29 October 2009.
-
- Assessment of natural ventilation effectiveness for an active NetZero energy house
- This study was undertaken to investigate the effectiveness of an integrated natural ventilation design for a NetZero energy house in maintaining occupants comfortable solely by passive means. The house was instrumented and monitored during the warmest months of the year. A dynamic thermal model and a computational fluid dynamics (CFD) model were developed to supplement the measurements and help to understand the factors that contribute to the effectiveness of the design. A methodology was developed to validate the models with data and cross-validate them. Adaptive thermal comfort is used as the metric to determine if comfort has been achieved. The study concludes that the house as a whole meets the comfort target. Two technologies were compared through simulations to evaluate their effect on enhancing wind-induced natural ventilation. The technologies did not improve cooling performance in a significant manner. Further work is needed to improve the models through technologies testing in the laboratory and model the uncertainty of the boundary forces to increase confidence in the results., Peer reviewed, Peer reviewed article, Published online: 06 Sep 2016., Adaptive thermal comfort, Natural ventilation, Active house, NetZero energy house